Holter monitors
CARDIOTECHNICA CT-07-AD-1
Advantages
- Blood pressure monitoring by two methods
- Continuous recording of a single ECG lead, patient activity and body position
- Recording of Korotkoff tones and cuff pressure
- The microphone allows operation through clothing
- The shape of the cuff prevents slippage
- Automation of control measurements
- Quality control of the measurements made on the monitor display
1 600 €
1 600 €
Description
Continuous recording of 1 ECG lead allows for an extraordinary start of blood pressure measurement
by ECG (for tachycardia, bradycardia, ischemia...), provides additional information (heart rate dynamics,
detection of arrhythmias, assessment of variability of RR intervals).
Using two methods for determining blood pressure and automatic selection of a method in the process blood pressure monitoring provides greater immunity to interference and the reliability of the results on the ABPM monitor: measuring blood pressure only by oscillometric method for noise in the microphone channel or only using the method Korotkoff with fluctuations in pressure in the cuff, for example, due to physical activity of the patient.
Signal recording (Korotkoff sounds, cuff pressure) allows you to check any measurement (you can do conclusions based on a single measurement).
Automated procedure control measurement.
Functionality of the KT-07-AD-1 recorder
- measurement of blood pressure by a combination of two methods: Korotkoff sounds and oscillometric with ECG synchronization;
- recording body position and motor activity of the patient with two motion sensors (external and internal);
- registration of one ECG lead for reliable measurement of blood pressure in patients with severe arrhythmias;
- built-in wireless interface.
Using two methods for determining blood pressure and automatic selection of a method in the process blood pressure monitoring provides greater immunity to interference and the reliability of the results on the ABPM monitor: measuring blood pressure only by oscillometric method for noise in the microphone channel or only using the method Korotkoff with fluctuations in pressure in the cuff, for example, due to physical activity of the patient.
Signal recording (Korotkoff sounds, cuff pressure) allows you to check any measurement (you can do conclusions based on a single measurement).
Automated procedure control measurement.
Functionality of the KT-07-AD-1 recorder
- measurement of blood pressure by a combination of two methods: Korotkoff sounds and oscillometric with ECG synchronization;
- recording body position and motor activity of the patient with two motion sensors (external and internal);
- registration of one ECG lead for reliable measurement of blood pressure in patients with severe arrhythmias;
- built-in wireless interface.
Specifications
-
Weight
184 gr. -
Size
85 mm / 56 mm / 23 mm
Software functions
| BP variability | |
| Circadian index assessment | |
| Obtaining the results of all measurements in a tabular format | |
| Obtaining summary tables containing average BP values during the day, day and night | |
| Maximum and minimum blood pressure values per day, day and night | |
| Table of hypotensive and hypertensive pressure loading indices | |
| Table of analysis of the daily rhythm of blood pressure measurement | |
| Analysis of nocturnal BP decline, analysis of morning BP rise rate | |
| Automatic comments blood pressure dynamics in relation to norms | |
| Relationship between HR and BP | |
| Calculation of RR-interval variability | |
| Assessment of HR dynamics with automatic comments for the norms | |
| Generation of a "clinical" report with the possibility of correction and editing by the physician | |
| Assessment of dynamics at follow-up |